• SENATOR COUNTRYMAN System- Boilers Installation & Users Guide. • - PLASTIC PIPE - CAPACITIES OF EXPANSION VESSEL - EXPANSION VESSEL SIZING - WARNING SEALED SYSTEM - FILLING SYSTEM - SENATOR CONVENTIONAL FLUE INSTALLATION - BALANCED FLUE INSTALLATION (INTERNAL) 13-21 - CONNECTING OIL SUPPLY 21-22 - ELECTRICAL CONNECTION (INTERNAL & EXTERNAL) • INTRODUCTION Thank you for choosing the INTERNAL or EXTERNAL COUNTRYMAN COMBI oil boiler please read the following carefully.


To the installer This manual must be left with the householder by the installer who will instruct the user on the boiler operation. To the user Please read the user section of this manual to familiarize yourself with the boiler operation. • USER INSTRUCTIONS Boiler Control Thermostat BOILER OPERATION The Boiler Control Thermostat responds to the temperature of the water within the boiler and switches power to the burner when heat is required. The burner has an independent control system which regulates the firing and (shut-off) of the burner. • BOILER CONTROLS BOILER CONTROL THERMOSTAT The temperature of the water within the boiler is controlled and maintained by the Boiler Control Thermostat located on the boiler control panel. TEMPERATURE SETTINGS: The Boiler Control Thermostat has a range of 50˚C to 80˚C.
The recommended setting for the boiler control thermostat is: WINTER Heating and hot water supply 80˚C. • SWITCHING THE BOILER OFF The boiler can be turned off by turning the rocker switch, located on the underside of control panel, to the OFF position. Ken Park Full 300 Rip. PLEASE NOTE: For longer periods of shutdown e.g. While away on holiday, switch OFF the mains (electrical supply) and turn OFF the OIL supply. • RESTART - Check there is adequate oil in the storage tank. - Check oil supply valves are open.
- Switch on heating system (e.g. - Depress the red Burner Reset Button on the burner Control Box, which will be illuminated. Both Burner Reset Button (illuminated) and the lockout Indicator on the Control Panel will go out and the burner will commence the ignition start sequence. • REGULATIONS The installation of oil fired boilers should comply with the following standards and codes of practice.
- BS5449 Forced circulation hot water heating systems for domestic use - BS5410-Part1 Oil installations up to 45kw. - BS7593 Water treatment of hot water central heating systems. - BS7671 Electrical Regulations. • BOILER LOCATION Sound levels should be discussed with the householder, as some people may be sensitive to low noise levels in a small room, as it may appear more annoying than in a larger room. Please Note installation should take into account of flue position (see diagram).